Solid Laq

Matt water-borne two-component polyurethane lacquer for concrete floors.

EPD verified
M1
Key FlagKey Fl
CE
  • 8015
  • 7 m²/l
  • 20 m²/l
  • 24 h
  • 0.5 h

Finish

  • Matt

Documents
Product Data
Description

Matt water-borne two-component polyurethane lacquer for concrete floors.


Product Features

Dust binding for concrete floors. Also suitable to be used as a matt topcoat for Solid floor paints. For professional use only.


Recommended Uses

Suitable for concrete floors on moderate stess. Solid Laq binds dust and leaves the concrete look matt and natural.


Technical Information
Coverage

Untreated concrete 7–12 m²/l Top lacquering 10–20 m2/l Practical coverage depends on the porosity and evenness of the substrate.


Thinner

Waterborne


Guidelines
Application Conditions

The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +10ºC during application or drying. Relative humidity of air should not exceed 90%.


Surface preparation

New concrete floor: Remove the laitance layer from the concrete surface by, for example, surface sanding or hydrochloric acid pickling. Remove laitance dust carefully after sanding. Hydrochloric acid pickling is performed with a diluted solution (1 part concentrated hydrochloric acid, 4 parts water). Rinse the floor with plenty of water. The substrate has to be dry, firm and solid before surface treatment. Painted concrete floor: Clean the floor and remove any grease, oil, chemicals and other impurities with Tikkurila Maalipesu cleaning agent. Sand the surface carefully and remove the sanding dust.


Painting

First coat:

Prime with Solid Laq thinned 10-20 % with water. The thinner is added to the ready compound and mixed carefully. Finish with Solid Laq thinned 10-20 % with water. Pour the mixture on the floor and apply thinly by roller or spatula. Note! Add the remaining mixture to the next batch of the product, do not scrape it out of the container onto the floor.


Maintenance Instructions

The lacquered surface will reach its final wear and chemical resistance approx. 2 weeks after the surface treatment. Avoid cleaning during this time. Clean the surface with a brush, mop or dust cloth. Dirty surfaces can be cleaned with a cleaning tool and a neutral (pH 6–8) washing solution.


VOC

VOC 2004/42/EC (cat A/j) 140 g/l (2010) Solid Laq contains VOC < 140 g/l.